TSI Q-Track IAQ Monitor with Model 982 Probe and Datalogging
The Q-Track Monitor (model 7575) from TSI is an indoor air quality monitor. This particular monitor comes with a model 982 IAQ probe for CO, CO2, temperature and humidity monitoring.
As standard the Q-Trak Indoor Air Quality Monitor will display up to five measurements simultaneously. It has a datalogging capability and the ability to download statistics and data for analysis and reporting. TrakPro software is required for this, which is provided with the instrument.
The Q-Trak IAQ monitor is provided alongside a hard-carrying case, USB cable for download, universal power supply, four alkaline batteries, a manual and a calibration certificate.
Key Features
Handheld monitor
Lightweight and easy to carry
Compatible with a range of other plug-in probes
Suitable for various applications – IAQ investigations, industrial hygiene surveys, baseline trending and screening, building commissioning, tracking down emissions to their source (point source location)
Monitor Dimensions
9.7 x 21.1 x 5.3 cm (3.8 x 8.3 x 2.1”)
Probe Dimensions
17.8 x 1.9cm (LxD) / 7.0 x 0.75”
Weight (with batteries)
0.36 kg (0.8lbs)
Power Requirements
4 x AA alkaline batteries (or AC adapter, both are included)
Log Intervals / Capabilities
1 second up to 1 hour (user selectable)
Logs up to 56,035 data points with key (4) measured parameters enabled, 39 days at 1-minute log intervals
Time Constants
1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable)
Temperatures
Operating Temperature – 5 to 45°C (40 to 113°F)
Storage Temperature – -20 to 60°C (-4 to 146°F)
Barometric Pressure
Range – 517.15 to 930.87 mm Hg (20.36 to 36.648 in. Hg)
Accuracy – ±2% of reading
% Outside Air
Range – 0 to 100%
Resolution – 0.1%
Probe Sensor Type
Carbon Monoxide (CO) – Electro-chemical
Carbon Dioxide (CO2) – Dual-wavelength NDIR (non-dispersive infrared)
Temperature – Thermistor
Relative Humidity – Thin-film capacitive
Probe Range
Carbon Monoxide (CO) – 0 to 500ppm
Carbon Dioxide (CO2) – 0 to 5,000 ppm
Temperature – 0 to 60°C (32 to 140°F)
Relative Humidity – 5 to 95% RH
Probe Accuracy
Carbon Monoxide (CO)5 – ±3% of reading or 3 ppm, whichever is greater
Carbon Dioxide (CO2)6 – ±3.0% of reading or ±50 ppm, whichever is greater
Temperature3 – ±0.5°C (1.0°F)
Relative Humidity4 – ±3% RH
Probe Resolution
Carbon Monoxide (CO) – 0.1 ppm
Carbon Dioxide (CO2) – 1 ppm
Temperature – 0.1°C (0.1°F)
Relative Humidity – 0.1% RH
Probe Response Time
Carbon Monoxide (CO) – <60 seconds to 90% step change
Carbon Dioxide (CO2) – 20 seconds
Temperature – 30 seconds (90% of final value, air velocity at 2 m/s [400 ft/min])
Relative Humidity – 30 seconds (90% of final value, air velocity at 2 m/s [400 ft/min])
3 Accuracy with instrument case at 25°C (77°F), add uncertainty of 0.03°C/°C (0.05°F/°F) for change in
instrument temperature.
4 Accuracy with probe at 25°C (77°F). Add uncertainty of 0.2% RH/°C (0.1% RH/°F) for change in probe
temperature. Includes 1% hysteresis.
5 At 25°C (77°F). Add uncertainty of 0.36%/°C (±0.2%/°F) for change in temperature.
6 At calibration temperature. Add uncertainty of 0.5%/°C (±0.28%/°F) for change in temperature